Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Enables the domain fill mode. The possible values are as follows:

  • noneno: domain fill is disabled
  • full: in this mode the the particles are not released at specific locations but the 3D-volume of the first release is taken and the particles are uniformly distributed in the volume proportionally to air density. Each particle will receive the same mass, altogether accounting for the total atmospheric mass. Subsequently, particles can move freely in the atmosphere.
  • o3_tracer: in this mode domain-filling is to simulate a stratospheric ozone tracer. This option is similar to fill option, but only particles in the stratosphere (defined by PV < 2 pvu) are released.

The default value is none no.

Sensitivity

Enables computing sensitivity to initial conditions in backward simulations. The possible values are none no, mass (mass concentration units) or mixr (mass mixing ratio units). The default value is none.