  • Each partner will provide their eps data on a 0.25/0.25 regular lat-lon grid (1440x721 grid points, including poles).
  • First grid point is 90N 0E. The data will be archived first from west to east (OE to 358.5), and then from north to south (90N to 90S).
  • The related GRIB 2 meta data called scanning mode  should equal to 0.
    • Scanning mode 0

      • i scans positively (west to east)
        • i points are consecutive
      • j scans negatively (north to south)

      Image Modified

  • The fields have to be provided on...
  • Grids are defined in GRIB2 using an accuracy of 1/1000000 (one millionth) of a degree.

Data compression

CCSDS compression should be used

GRIB2 encoding

All data must be encoded following the required rules described below to achieve fully compliant WPMIP format from all centres.

...

*2 New codes for the WPMIP (part of GRIB 2 tables version 36) to be approved by WMO by August 2025 (Manual on Codes (WMO-No. 306), Volume I.2, GRIB code table 1.3)


Section 4
Octets
Value (Example perturbed)Value (Example control)
8-9
product definition template number
productDefinitionTemplateNumber

1/11* 

1/11*

13
background process
backgroundProcess



14
generating process identifier
generatingProcessIdentifier



35
type of ensemble forecast
typeOfEnsembleForecast255 (missing) 255 (missing) 
36
perturbation number
perturbationNumber70
37
number of forecasts in ensemble
numberOfForecastsInEnsemble5151

(*) statistically processed (typeOfStatisticalProcessing is set up)

Section 5
Octets
ValueDescription
10-11
data Representation Template Number
dataRepresentationTemplateNumber

42

[Grid point data - CCSDS recommended lossless compression (grib2/tables/29/5.0.table) ]


WMO Centre codes