Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Section


Column
width76px


Column

This icon runs the FLEXPART Lagrangian particle dispersion model and converts its outputs to formats that Metview can work with. For help on editing icons, please see Editing Icons.

The macro language equivalent is flexpart_run().


...

Specifies the location of the output data files. Both an absolute and relative path can be given here. Please note that Metview converts FLEXPART output into other formats and only these converted results are copied from the work directory into Output Path. For further details about the output formats please click here.

Input Data

Specifies the location of the input data files and the AVAILABLE file using a FLEXPART Prepare icon. Please note that if an icon is set here it takes precedence over the path specified in Input Path.

...

Specifies the location of the input data files and the AVAILABLE file. Both an absolute and relative path can be given here. Please note that when an icon is specified in Input Datathe this path specified here is ignored.

User Exe Path

Specifies a user defined FLEXPART executable. Both absolute and relative path can be given here. If it is left blank (this is the default) Metview will use the MV_FLEXPART_EXE environment variable to locate the executable.

...

Specifies the location of the user defined parameter files (IGBP_int1.dat, OH_7lev_agl.dat, surfdata.t, surfdepo.t ) needed to run FLEXPART. Both an absolute and relative path can be given here. If it is left blank (this is the default) Metview will use the MV_FLEXPART_RESOURCES environment variable to locate the resources. For further details about the resources click here.

Simulation Direction

Specifies the FLEXPART simulation direction in time. The possible values are: Forward and Backward. The default value is Forward.

...

Specifies the ending time of the simulation in HH[:MM[:SS]] format. 

Output

...

Interval

Specifies the frequency for the output generation. The output is averaged over the period given in Output Averaging Interval. The format is HHHH[:MM[:SS]]. The default value is 3 (hours).

...

Specifies the sampling rate used for the averaging of the output. This period must be shorter than the Output Averaging Interval. The format is HHHH[:MM[:SS]]. The default value is 1 (hour 0:15 (15 minutes).

Output Field Type

Specifies the type of the gridded output fields. The possible values are:

for forward simulations:

  • none (no gridded output)
  • conc (concentration)
  • mixr (mass mixing ratio)
  • both (concentration and mass mixing ratio)

for backward simulations:

  • none (no gridded output)
  • rtime (residence time/response function)

The default value is conc. . For more details about gridded output click here.

Output Flux

Specifies if the fluxes should be computed and written out as a gridded output (on or off). Fluxes corresponding to northward, southward, eastward, westward, upward and downward directions are calculated for each grid cell of the output grid.The control surfaces are placed in the middle of each output grid cell. The default value is off. For more details about flux output click here.

Output Trajectory

Specifies if the plume trajectories should be computed (on or off). The default value is off.  For more details about trajectory output click here.

Output Area

Specifies the area for the gridded output in degrees in S/W/N/E format. The default value is  -90/-180/90/180.

...

Specifies the location of the user defined species files. Both an absolute and relative path can be given here. If it is left blank (this is the default value) Metview will use the MV_FLEXPART_SPECIES environment variable to locate the species.   For more details about the species click here.

Release Species

Specifies the list of the species released for the simulation. At all the release locations the same species are emitted. The species are identified by the NNN number (with leading zeros) appearing in the the name of the SPECIES_NNN files. These files contain the physical and chemical properties of species. For more details about the species click here.  

Release Units

Specifies the units of the mass of the released species. The possible options are mass and mixr. The default value is mass. See the table below to figure find out what the actual units mean.

...

for forward simulations:

Release UnitsReceptor Units
keywordunitskeywordunits in
output
concentration
grib
fields
(generated when Output Field Type = conc or both)
Forward
masskgmasskg m**-3
Forward
masskgmixrkg kg**-1
Forward
mixr1masskg m**-3
Forward
mixr1mixrkg kg**-1

for backward simulations:

Release UnitsReceptor Units
keywordunitskeywordunits in residence time fields
Backward
mass1masss
Backward
mass1mixrs m**3 kg**-1
Backward
mixr1masss kg m**-3
backward
mixr1mixrs

Releases

Specifies the releases as a group of FLEXPART Release icons. 

...

Specifies the concentration units at the receptor. For forward simulations this the units of the output concentrations. For backward simulations ????? The possible options are mass (mass concentrations) and mixr (mass mixing ratio). The default value is mass.  See the table above to find out what the actual units mean.

Receptors

Enables the usage of receptor sites for forward simulations (on or off). When it is enabled the list of receptor sites can be defined via Receptor Names, Receptor Latitudes and Receptor LongitudeLongitudes. The default value is off. For more details about receptor output click here.

Receptor Names

Specifies the list of receptor site names.The default value is an empty list.

...

Specifies the list of receptor site latitudes. The default value is an empty list.

...

Receptor Longitudes

Specifies the list of receptor site longitudes. The default value is an empty list.

...

Specifies the factor by which the time step must be smaller than the Lagrangian time scale (TL). CTL must be >1 for time steps shorter than the Lagrangian time scale. If CTL<0, a purely random walk simulation is done. The default value -45.

Vertical Timestep Reduction

...

Enables convection parametrization (on or off). The default value is off.

Output For Each Release

Specified Specifies whether a separate output fields should be generated for each release separately (on or off). When this option is set to off for forward simulations the output fields for a given species contain the sum of all the releases. For backward simulations it must be set to off on. The default value is off.

...

Enables the domain fill mode. The possible values are as follows:

  • no: domain fill is disablednone
  • full: in this mode the the particles are not released at specific locations but the 3D-volume of the first release is taken and the particles are uniformly distributed in the volume proportionally to air density. Each particle will receive the same mass, altogether accounting for the total atmospheric mass. Subsequently, particles can move freely in the atmosphere.
  • o3_tracer: in this mode domain-filling is to simulate a stratospheric ozone tracer. This option is similar to fill option, but only particles in the stratosphere (defined by PV < 2 pvu) are released.

The default value is none.

Dump Particle Position

Enables dumping the particle positions. The possible values are none, output (at every output time) and end (only at the end of the simulation). The default value is none.

no.

Sensitivity