Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This example represents a  6-hour minimum of a field valid on 20120103 00Z produced by a forecast started on 20120101 00Z . In this example, the minimum is the 6-hourly minimum in the time interval: steps 42 to 48.


  • In bold, the values are fixed. They are meant to be used by all partners
  • In green, these are the values for the example.

 

=  201215= 01= 1=  2012  = = 1= 0= 3= = 1= 6= 1= 0
Time (Minimum over the last 6 hours )
Start of re-forecast ( section 1 )

Octets

reforecast

Octets

real time

 

Fixed values

to be used by

all the partners

 

Example


 Meaning of  valuesGrib_api keys
121212Significance of Reference Time1Start of forecast= 1 
13-1413-14Year (four digits)2012year of start of forecast

 

dataDate=

20120101

dataTime=0

15Month 01month of start of forecast= 01
1616Day 01day of start of forecast
1717Hour 00hour of start of forecast= 00
Minimum ( section 4 e.g. Template 4.11)
1818Indicator of unit of time range 1Hour= 1 
19-2219-22Forecast time 42Step at the beginning of the 6-hourly intervalstartStep=42
45-4638-39year of end of overall time interval 2012

 

End of minimum period

 

endStep=

48

4740month of end of overall time interval 01= 01
4841day of end of overall time interval 03= 03
4942hour of end of overall time interval 00
5245number of time ranges 1Only one time statistics applied (minimum)= 1 
53-5646-49total number of data values missing in statistical process 0 = 0 
5750

Statistical process used to calculate the processed field

from the field at each time increment during the time range

 3MinimumstepType= 3min
5851

Type of time increment between successive fields

used in the statistical processing

2

Successive times processed have same start time of forecast, forecast time is incremented

= 2 
5952

Indicator of unit of time for time range

over which statistical processing is done

 1HourindicatorOfUnitForTimeRange=1
60-6353-56

Length of the time range over which statistical

processing is done, in units defined by the previous octet

 66-hourly maximumminimumlengthOfTimeRange=6
6457

Indicator of unit of time for the increment between

the successive fields used

 1HourindicatorOfUnitForTimeIncrement=1
65-6858-61

Time increment between successive fields,

in units defined by the previous octet

 0Minimum computed continuously in the 6 hourly intervaltimeIncrement=0 

 

Examples of grib2 headers: