Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Expand
titleClick here to expand the list of related documents (D1-D4D5)


Reference ID

Document

D1

CM SAF ATBD: Algorithm Theoretical Baseline Document - HOAPS version 4.0
DOI: 10.5676/EUM_SAF_CM/HOAPS/V002
ATBD_CMSAF_HOAPS_4.0

D2

ValRep: Validation Report SSM/I and SSMIS products - HOAPS version 4.0
DOI: 10.5676/EUM_SAF_CM/HOAPS/V002
ValRep_SSM/I_SSMIS_HOAPS_4.0

D3

ATBD: Algorithm Theoretical Baseline Document - Total Column Water Vapour
brokered from EUMETSAT CM SAF(1988-2014) & ICDR – C3S (2015-2020) from SSM/I & SSMIS measurements
C3S_D312b_Lot1.1.3.3-v1.1_202102_ATBD_TCWV_SSMIS_TCDR+ICDR_v1.1

D4

Product Quality Assurance Document - Total Column Water Vapour
brokered from EUMETSAT CM SAF(1988-2014) & ICDR – C3S (2015-2020) from SSM/I & SSMIS measurements
C3S_D312b_Lot1.2.3.8-v1.1_202102_PQAD_TCWV_SSMIS_TCDR+ICDR_v1.1

D5

Report on Updated KPIs.
Key Performance Indicators (KPIs)


Acronyms

Expand
titleClick here to expand the list of acronyms


Acronym

Definition

AIRS

Atmospheric Infra-Red Sounder

CDR

Climate Data Record

CM SAF

Climate Monitoring Satellite Application Facility

COSMIC

Constellation Observing System for Meteorology, Ionosphere, and Climate

DMSP

Defense Meteorological Satellite Program

ECMWF

European Centre for Middle-range Weather Forecast

ERA

ECMWF Re-Analysis

HOAPS

Hamburg Ocean & Atmosphere fluxes and Parameters from Satellite data

ICDR

Interim Climate Data Record

IQR

Inter Quartile Range

NASA

National Aeronautics and Space Administration

RMSD

Root Mean Square of Differences

SSM/I

Special Sensor Microwave Imager

SSMIS

Special Sensor Microwave Imager Sounder

TCDR

Thematic Climate Data Record

TCWV

Total Column Water Vapour

TMI

TRMM Microwave Imager

TRMM

Tropical Rainfall Measurement Mission


...

The KPI test of ICDRs vs. TCDRs leads to similar conclusions. The ICDR differences relative to the RSS_SSMI and ERA-5 validation datasets stay in the expected range for TCDRs (Table 4). Only 5 out of 72 ICDRs show larger differences, which is expected from the 95% confidence interval. On the other hand, due to large drift between HOAPS 4.0 SSMI(S) and AIRS V7, the number of ICDR failures (K=30) exceeds the critical number of 7. Hence the ICDR differences between HOAPS & AIRS V7 do not fulfill the null hypothesis of similarity between ICDRs and TCDR. Further details can be found in the PQAD [D4] and Report on Updated KPI's [D5].

Anchor
table4
table4
Table 4: Results of the hypothesis test upon the number of ICDRs falling outside the 95% confidence interval of the TCDR.

...