Specifies the data input mode. The possible values are: Icon and Path.
In Icon mode a set of GRIB icons has to be specified in Vapor Input Data. If the mode is set to Path a period with a start and end date and constant time-step can be defined. In this case FLEXTRA Prepare tries to retrieve analysis fields from MARS whenever it is possible (for dates in the past) and uses forecast fields otherwise (for dates in the future).
Specifies the input data as a set of GRIB icons. It is available when Vapor Input Mode is Icon.
Specifies the list of surface parameters from the input data to be converted into VAPOR format. The parameters are identified by their short names. The default value is an empty string.
Specifies the list of the upper level parameters from the input data to be converted into VAPOR format. The parameters are identified by their short names. The default value is an empty string.
Specifies the type of the upper level data to be used in VAPOR. The possible values are: Layered and Regular.
If the type is set to Layered VAPOR expects an upper level parameter specifying the elevation of each atmospheric. Internally in VAPOR this parameter is called ELEVATION. The default value is Layered.
Specifies the name of the upper level parameter interpreted as the elevation of the upper levels. Available when Vapor Vertical Grid Type is Layered.
The name of the upper level GRIB parameter interpreted as the elevation of the upper levels. Available when Vapor Vertical Grid Type is Layered.
The name of the upper level GRIB parameter interpreted as the elevation of the upper levels. Available when Vapor Vertical Grid Type is Layered.
The name of the upper level GRIB parameter interpreted as the elevation of the upper levels. Available when Vapor Vertical Grid Type is Layered.
Specifies the area of the output grid in south/west/north/east format. The default value is -90/-180/90/180.
Specifies the resolution of the output grid in dx/dy format, where dx is the grid increment in east-west direction, while dy is the grid increment in north-south direction (both in degrees units). The default value is: 1/1.
Specifies the resolution of the output grid in dx/dy format, where dx is the grid increment in east-west direction, while dy is the grid increment in north-south direction (both in degrees units). The default value is: 1/1.
Specifies the resolution of the output grid in dx/dy format, where dx is the grid increment in east-west direction, while dy is the grid increment in north-south direction (both in degrees units). The default value is: 1/1.
Specifies the output directory (it has to be an absolute path) where the GRIB files and the AVAILABLE file will be generated. If this directory does not exist Metview will create it. The output GRIB files have the following naming convention: ENyymmddhh.
If this parameter is set On FLEXTRA Prepare checks the existence of the data files to be generated and if they are already in place no new data is retrieved and processed. If it is Off all the fields are always retrieved and processed and the existing data files are overwritten. The same happens to the AVAILABLE file. The existence of a FLEXTRA input GRIB file is checked by using the file name and a set of GRIB API keys from the first message in the file. These keys are as follows: date, time, stepRange, gridType, iDirectionIncrement, jDirectionIncrement, latitudeOfFirstGridPoint, latitudeOfLastGridPoint, longitudeOfFirstGridPoint, longitudeOfLastGridPoint.
The MARS experiment identifier of the analysis fields. The default value is 1 (operational analysis).
Specifies the run date of the forecast. Available when Flextra Prepare Mode is Forecast.
Specifies the run time of the forecast . Available when Flextra Prepare Mode is Forecast.
Specifies the forecast steps in hours. Here a list of values is given. Available when Flextra Prepare Mode is Forecast.
Specifies the start date of the period. Available when Flextra Prepare Mode is Period.
Specifies the start time of the period. Available when Flextra Prepare Mode is Period.
Specifies the end date of the period. Available when Flextra Prepare Mode is Period.
Specifies the end time of the period. Available when Flextra Prepare Mode is Period.
Specifies the time step of the period in hours. The allowed values are as follows: 3 or 6. Available when Flextra Prepare Mode is Period.
Specifies the area of the output grid in south/west/north/east format. The default value is -90/-180/90/180.
Specifies the resolution of the output grid in dx/dy format, where dx is the grid increment in east-west direction, while dy is the grid increment in north-south direction (both in degrees units). The default value is: 1/1.
Only data on and below this model level will be used to generate the FLEXTRA input fields. This level can be specified either as a model level or as a pressure value. In the latter case FLEXTRA Prepare will use the data retrieved for the first date to determine the topmost model level. The default value of this parameter is 1, which mens that all the model levels will be used if Flextra Top Level Units is set to Model Levels.
Specifies the units of the value of Flextra Top Level. The allowed values are Model Levels or hPa. The default value is Model Levels.
If this parameter is set On FLEXTRA Prepare checks the existence of the data files to be generated and if they are already in place no new data is retrieved and processed. If it is Off all the fields are always retrieved and processed and the existing data files are overwritten. The same happens to the AVAILABLE file. The existence of a FLEXTRA input GRIB file is checked by using the file name and a set of GRIB API keys from the first message in the file. These keys are as follows: date, time, stepRange, gridType, iDirectionIncrement, jDirectionIncrement, latitudeOfFirstGridPoint, latitudeOfLastGridPoint, longitudeOfFirstGridPoint, longitudeOfLastGridPoint.
Specifies the output directory (it has to be an absolute path) where the GRIB files and the AVAILABLE file will be generated. If this directory does not exist Metview will create it. The output GRIB files have the following naming convention: ENyymmddhh.
The name of the upper level GRIB parameter interpreted as the elevation of the upper levels. Available when Vapor Vertical Grid Type is Layered.