Specifies the main retrieval mode. The possible values are: forecast and analysis.
In forecast mode the selected steps of a given forecast can be used for data generation. If the mode is set to analysis a period with a start and end date and constant time-step can be defined.
Specifies the type of data to be retrieved from MARS. The possible values are: hires and ens. The default is hires.
In hires mode the operational deterministic forecast is retrieved. While in ens mode the operational ENS forecast (both "pf" and "cf" members) is used. If Mode is set to analysis this option is disabled and automatically set to hires.
Specifies the perturbed ensemble members to be retrieved as a list. The default value is: 1/TO/50. Only enabled when Product is set to ens.
Specifies the type of vertical levels. The possible values are: pl (pressure levels) and ml (model levels). The default value is: pl.
Specifies the list of pressure levels in hPa when Levtype is pl. The default value is: 1000/925/850/700/500/400/300.
Specifies the list of model levels when Levtype is ml. The default value is: -10
If the list of model levels is a sole negative number (-N) it means that all the model levels will be retrieved from the surface up to level N. Please note that model level numbering starts at the topmost atmospheric level (see here for level information) |
Specifies the list of surface parameters The default value is: 2t/10u/10v.
Please note that when the following precipitation rate parameters are specified:
their sum is computed and added as a tprate field to the results. |
Specifies the list of upper level parameters The default value is: t/q/u/v
Please note that on model levels z (geopotential) is not archived in MARS. However, when z is specified in Param_3D it will be automatically computed (the fields needed for the computations will also be automatically retrieved). To be able to plot "jet cores" in 3D z is needed. |
Specifies the run date of the forecast. Available when Mode is forecast. The default value is -1 (i.e. yesterday).
Specifies the run time of the forecast in hours. Available when Mode is forecast. The default value is 0.
Specifies the forecast steps in hours. Here a list of values can be given. Available when Mode is forecast. The default value is 0.
Specifies the start date of the analysis period. Available when Mode is analysis. The default value is -1 (i.e. yesterday).
Specifies the start time of the period. Available when Mode is analysis. The default value is 0.
Specifies the end date of the period. Available when Mode is analysis. The default value is -1 (i.e. yesterday).
Specifies the end time of the period. Available when Mode is analysis. The default value is 0.
Specifies the time step of the analysis period in hours. The allowed values are as follows: 6 or 12. Available when Mode is analysis. The default value is 6.
Specifies the area of the output grid in south/west/north/east format. The default value is -90/-180/90/180.
Specifies the resolution of the output grid in dx/dy format, where dx is the grid increment in east-west direction, while dy is the grid increment in north-south direction (both in units of degrees). The default value is: 1/1.
Specifies how the MARS retrievals should be executed. When it is set to ON the following happens:
When it is set to OFF each step/time is retrieved separately (in a loop). The default value is ON.