GRIB-API definition

NameMaximum temperature at 2 metresAbbreviationmx2tUnitKparamIdTBD

 

UERRA details

DefinitionThe maximum temperature near the surface determined since previous post-processing step.
ValidityMaximum determined since previous post-processing step.
Comment

Please note that the specific height level above ground might vary from one Centre to another.

 

WMO GRIB2 definition

Parameter
Discipline0meteorological products
Parameter category0temperature
Parameter cumber0temperature
Type of statistical processing2maximum
Length of time rangepost-processing step in hours
1/3/6
Level
Type of first fixed surface103 specified height level above ground (m)
Scale factor of first fixed surface0 or 1***(m) or (dm***)
Scaled value of first fixed surface2 or 15***2 / 1.5 m
Type of second fixed surfaceall bits to 1
missing
Scale factor of second fixed surfaceall bits to 1missing
Scaled value of second fixed surfaceall bits to 1missing