Computes the relative humidity from specific humidity fieldsets. This is a Metview icon function, for detailed documentation please see Relative Humidity.


Anchor
relative_humidity_from_dewpoint
relative_humidity_from_dewpoint

number relative_humidity_from_dewpoint(t: number, td: number)

vector relative_humidity_from_dewpoint(t: vector, td: vector)

fieldset relative_humidity_from_dewpoint(t: fieldset, td: fieldset)

Computes the relative humidity from the given temperature and dewpoint temperature, where

    • t: temperature (K)
    • td: dewpoint temperature (K)

The result is the relative humidity in the range of [0, 1]. On error for nil is returned. The computation is based on the following formula:

Mathdisplay
r = \frac{e_{wsat}(Td)}{e_{wsat}(T)}

where ewsat is the saturation vapour pressure over water.


Anchor
saturation_mixing_ratio
saturation_mixing_ratio

...