Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To create a new SCM run icon, drag a copy of it from the Modules (Data) icon drawer at the bottom of the Metview desktop. (Alternatively, right-click in the Metview desktop and select 'New Create new icon'. This will bring up the icon selection list where you can find Create new icon dialogue.  In the dialogue just type "scm" into the Filter field then  click on the SCM Run icon towards the bottom. Now click on it in the icon list and wait until the newly created icon appears in your folder.)

...

Finally, save your changes (by clicking Apply Save in the editor) then right click and execute the icon to start your SCM integration. The icon label turns orange indicating that the computations have started. Having finished the integration the icon label turns green showing that no errors occurred (on error the icon label turns red).

...

The output of an SCM run can be visualised using the SCM Visualiser icon, located in the Modules (Plotting) icon drawer or else available from the right-click 'Create new icon' desktop menu: 

This icon allows the generation of the following plot types (specified in the Scm Plot Type parameter) :

...

Make sure that only your desired variable is selected - you will have to de-select t_skin. Apply (save) the icon and right-click | Visualise it to get an on-screen plot.

...

Try the following settings to obtain a matrix plot:

Scm Plot TypeTime Height Matrix
Scm Output 2d VariablesLw Radiative Flux

If comparing two SCM runs, the first will be represented with coloured shading, whilst the second will be drawn with isolines only.

 

To obtain a set of profiles, try these settings:

Scm Plot TypeProfile
Scm Output 2d VariablesTemperature

...