Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

As the meteogram database has been moved to Bologna, the Metview meteogram service in Reading will no longer work by default. Rather than fixing the TC1 TC-1 jobs in Reading, we strongly recommend users to run these jobs to the Atos systems in Bologna. See example metgram batch job under https://confluence.ecmwf.int/display/UDOC/HPC2020%3A+realtime_metgram.sh. Note that you will need to load the new version of the ecmwf-toolbox.

TC1 jobs in Reading

When your TC1 jobs is up and running on the Atos systems in Bologna, please do stop your TC-1 jobs in Reading, by canceling the job in STANDBY mode with 'ecaccess-job-delete', e.g.:

No Format
$> ecaccess-job-list
22379170   ecgate     STDBY      0/1    Oct 26 11:49   [bc06h012 (222)] tc1_06bc.cmd
22345657   ecgate     DONE       1/1    Oct 25 11:50   [bc06h012 (222)] tc1_06bc.cmd
$> ecaccess-job-delete 22379170

Common errors

The SLURM directive '#SBATCH --workdir=<directory_name>', commonly used on ecgate in Reading is deprecated. On the ATos systems, you should use '#SBATCH --chdir=<directory_name>' instead.

Make sure you submit your TC1 TC-1 jobs to the correct ECaccess events; see command 'ecaccess-event-list'.  If your jobs is submitted to early with reference to the dissemination schedule, it will fail.

Do give your TC1 TC-1 jobs sufficient time with the SLURM directive '#QSUB --time=<HH:MM:SS>'.

...