Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

Description:
There are some isolated spots of one or a few grid points with wrong zero values in the fields of relative humidity (both at 2m and on pressure levels). It happened because of a wrong algorithm used for re-computation of the values from 0-1 interval to 0-100% (the supersaturation was set to 100% 0% instead of 0% 100% value).

The same issue can be probably found in cloud cover and albedo fields as well but its extent there is not known.

...