Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Your work requires input data which is produced by any of the ECMWF models. In such case it is possible to set up a specific dissemination stream which will send the required data to the HPCF. ECPDS allows for the "local" dissemination to a specific User ID (the User ID used to run time-critical work) so that only this recipient User ID can see the data and is similar to the standard dissemination to remote sites. This ”local” dissemination option is the recommended option.  The recipient User ID is responsible for the regular clean-up of the received data.

    If produced by ECMWF, your required data will also be available in the FDB and will remain online for a limited (variable depending on the model) amount of time. You can access these data using the usual ”mars” command. If your suite requires access to data which may no longer be contained in the FDB then your suite needs to access these data before they are removed from the FDB and temporarily store them in one of your disk storage areas.

    Warning

    For no reason should any of your time-critical suite tasks depend on data only available from the Data Handling System (MARS archive or ECFS). Beware that using a keyword value of "ALL" in any mars request will automatically redirect it to the MARS archive (DHS). Note also that we recommend you do not use abbreviations for a MARS verb, parameter or value in your mars requests. If too short, these abbreviations may become ambiguous if a new verb, parameter or value name is added to the mars language.


  2. Your work requires input data which is available at ECMWF but not produced by an ECMWF model. For example, your work requires observations normally available on the GTS e.g. if you are interested in running some data assimilation work at ECMWF. In such a case you can obtain the required observations from /ec/vol/msbackup/ on the Atos HPCF where they are stored by a regular extraction task which runs as part of the ECMWF operational suite. For any other data you may need for your time-critical activity and which is available at ECMWF, please ask your User Services technical contact.

  3. Your work requires input data which is neither produced by any of the ECMWF models nor available at ECMWF. You will then be responsible for setting up the required ”acquisition” tasks and establish their level of time criticality. For example, your suite may need some additional observations which improve the quality of your assimilation but your work can also run without them in case there is a delay/problem in their arrival at ECMWF. Please see the section ”Data transfers” for advice on how to transfer incoming data.

...