Table of Contents |
---|
SMHI datasets (HARMONIE/V1, HARMONIE/V2)
Wrong 0% values in relative humidity, cloud cover and albedo fields
Info |
---|
Description: There are some isolated spots of one or a few grid points with wrong zero values in the fields of relative humidity (both at 2m and on pressure levels). It happened because of a wrong algorithm used for re-computation of the values from 0-1 interval to 0-100% (the supersaturation was set to 100% instead of 0% value). The same issue can be probably found in cloud cover and albedo fields as well but its extent there is not known. |
Missing values in surface sensible heat flux and surface latent heat flux fields
Info |
---|
Description: The sensible heat flux and surface latent heat flux fields appear to have missing values over the land and because of that should not be used. |
MO datasets (UM, UM/En)
The wind directions are wrong by exactly 180 degrees
Info |
---|