You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

SMHI datasets (HARMONIE/V1, HARMONIE/V2)

Wrong 0% values in relative humidity, cloud cover and albedo fields

Description:

There are some isolated spots of one or a few grid points with wrong zero values in the fields of relative humidity (both at 2m and on pressure levels). It happened because of a wrong algorithm used for re-computation of the values from 0-1 interval to 0-100% (the supersaturation was set to 100% instead of 0% value).

The same issue can be probably found in cloud cover and albedo fields as well but its extent there is not known.

Missing values in surface sensible heat flux and surface latent heat flux fields

Description:

The sensible heat flux and surface latent heat flux fields  appear to have missing values over the land and because of that should not be used.

MO datasets (UM, UM/En)

The wind directions are wrong by exactly 180 degrees

Description:

The wind directions are wrong by exactly 180 degrees (the direction is the wind is blowing to, rather than where it is blowing from) The U/V components  are not affected.

  • No labels