Functions

The most basic way to group lines of Macro code is into a function. Let's write a function to compute wind speed given its U and V vector components.

We've already written code to compute wind speed:

speed = sqrt(u*u + v*v)

We can easily create a function around this code, taking u and v as input parameters. Create a new Macro icon and call it wind_speed. Enter the following into it:

function wind_speed(u, v)
    speed = sqrt(u*u + v*v)
    return speed
end wind_speed

Within the same macro, read in some wind data and call the function, plotting the result:

u = read('wind_u.grib')
v = read('wind_v.grib')
speed = wind_speed(u,v)
plot(speed)

Note that it does not matter where the function is defined in the macro - it will be found.

We could restrict the function so that it only accepts fieldset data:

 function wind_speed(u:fieldset, v:fieldset)

This can be useful in some cases, but here the functionality is so general that it will work with fieldsets, geopoints, numbers and vectors - so we can leave this restriction out. See the supplied Syntax Sheet for more examples of how to define functions.

Including Other Macros

Now split the macro into file separate files: wind_speed should have the function definition, and call_wind_speed should read the GRIB data, call the function and plot the data (it should not work now, because it cannot find the function).

The include command literally includes the text of any macro at the insertion point. In our current example to make the function available to the call_wind_speed macro, it is enough to add the line:

include "wind_speed"

anywhere in the macro.

The included macro is read at the point where the include instruction is found. You can specify absolute or relative path names (relative to the position of the macro being run).

In this way you can place small libraries of functions in macro files, stored in a folder of your choice, ready for inclusion.

Inclusion does not require the included macro to be a self contained program or function, any partial fragment of code can be included, for example some variable declarations.

An include statement is interpreted before the rest of the macro is executed, including lines that precede the include statement. This means that you cannot, for instance, use a dynamically generated path to find the file to be included.

Function in a User/System Library

This is the method that can be really described as building a library of functions. Its principle is very simple - place macro functions in a particular folder which is searched by the function look- up procedure so they can be called from any macro program without the need for an include statement.

In our case, simply drag the wind_speed macro icon to the folder ~/metview/System/Mac­ros. From then on you can call this function from within any of your macros. Note that this only works when the name of the macro file is the same as the name of the function it contains. Remove the include statement from your call_wind_speed macro and see if it still works (it should). If you rename the wind_speed macro, it should no longer work.

This allows you to build your own personal function library. For a function to be available to other users, you can place the macros with the functions into shared folder on the file system; all users will need to set the environment variable METVIEW_MACRO_PATH to this location before starting Metview.

 

 